Instanta water boiler repair services | Catercare
top of page

Bedfordshire based commercial catering engineers serving the surrounding areas including:

 

Bedfordshire Catering Equipment Repair

Buckinghamshire Catering Equipment Repair

Hertfordshire Catering Equipment Repair

Oxfordshire Catering Equipment Repair

Cambridgeshire Catering Equipment Repair

Berkshire Catering Equipment Repair

Essex Catering Equipment Repair

North London Catering Equipment Repair

 

For breakdown repairs call us on: 01582 862000

 Instanta Repairs

by CaterCare Catering Equipment Ltd

Instant design and manufacture a range of robust commercial water boilers for the commercial catering, hotel and beverage industry.

 

We are able to repair the full range including:

 

  • Instanta countertop water boiler repair

  • Instanta wall mounted water boiler repair

  • Instanta undercounter water boiler repair

  • Instanta steam boiler repair

Book a service engineer today call:
01582 862000
or complete and submit the form below:

Thanks for submitting!

TROUBLESHOOTING GUIDE

A flashing green light indicates that the bottom probe is coated in limescale, in this instance it is recommended that the unit is fully descaled.

A flashing orange light can indicate that the unit does not have water coming into it, this can be as a result of the water supply being turned off, the inlet hose being kinked or bent or having very low water pressure.

A flashing red light can indicated that a safety control has activated or that an internal component has failed or that the unit has over filled due to limescale on the probes or a failed solenoid valve.

A flashing red and green light can indicate that the over boil safety stat has tripped on the initial heat up, due to over boiling, or boiling dry or due to a faulty element.

Reset the boiler

All Earlier Models: Switch off at the mains power supply and allow the boiler to cool for ten minutes.

Safety Caution: Isolate boiler from power supply sensors before proceeding:

Later Models (All 1000-M models and 1000-C units from Serial No: CB02863 – Jan 2014): Isolate from mains electrical power supply and allow the boiler to cool down. Remove back panel and push the small reset button in the centre of the over-boil

cut-out (located next to the water inlet valve).

If the problem still occur contact our Service Department on 01582 862000.

bottom of page